Only the instrument panel glass is to be replaced
If other parts of it are faulty, the entire instrument panel must be replaced
Disconnect the wires from the battery terminals, starting with the negative terminal.
Having taken the visor of the instrument panel with both hands, lift it and move it in the direction of the arrows.
The visor is spring-loaded to the dashboard.
Using a Torx 20 screwdriver, unscrew the instrument panel mounting screw.
By pressing the plastic tabs on both sides at the same time…
...raise the instrument panel
Disconnect the instrument panel power connector
Install
Installation is performed in the reverse order of removal.
Connect the battery without programming.
Perform the required configuration.
Disconnect the battery.
This operation automatically registers instrument panel configurations.
Connect the battery and do the necessary programming.
Tighten the bolts securing the battery cover to the required torque of 4 Nm.